19" Server Cabinets PRO, 800x800 mm, 1-Part Doors
Produktinformation til 19" Server Cabinet PRO 33U, 800x800 mm, F+R 1-Part, RAL9005
Steel sheet housing with screwed frame, completely pre-assembled, self-ventilated, detachable
Inside front and rear 4 x 19"profiles (2 front, 2 rear-sided), galvanised, step-less depth-adjustable
Contrariwise numbering of rack units at the 19" profiles
Front and rear door with 3-point turning handle (up to 24U 1-point), lockable, incl. profile half-cylinder acc. to DIN18252 / EN 1303
Profile half-cylinder exchangeable by customer (30/10 mm)
Door stop for front and rear door possible left- or right-sided
Detachable side walls with 2 x latch locking (lock equal to the door lock)
Cabinets stackable side-by-side with and without removal of the side walls, baying set (Art.-No. PRO-ANR0X), otherwise screwable via screw set M6
Roof and bottom with 4/6 pre-punched openings for cable entry (450 x 90 mm), for 600 mm cabinet width cable entry only rear
Roof prepared for accommodation of 2-fan or 4-fan units, bottom with pre-punched opening for filter or cable entry modules
Internal earthing of all cabinet sections
Pre-assembled earthing bar rear-sided in the middle of the cabinet (ports: 20 x M5 + 2 x 8 mm)
Max. load 1000 kg (depths 600 / 800 mm) resp. 1360 kg (depths 1000 / 1200 mm for >24U)
Paint finish RAL9005, jet black
Protection degree IP20
Included accessories: 1 x brush, 1 x set of captive nuts (PU 20 pcs.), earthing bar and earthing cables, 4 x levelling feet M12, 2 x key
Delivery in transport packaging on disposable pallet
Tekniske egenskaber
| Active air conditioning: | False |
|---|---|
| Air inlet floor: | Breakout opening type A (380 x 380 mm), e.g. for filter or cable entry modules |
| Cabinet Series: | PRO |
| Cable entry roof/floor: | Roof and base each with 4 pre-cut, breakable openings, all around, each 450 x 89 mm (re-sealable with a 19" 2U blanking plate) |
| Category: | 19" server cabinet according to DIN41494 |
| Degree of protection: | IP20 according to EN60529 |
| Demountable: | True |
| Door hinge reversible front door: | True |
| Door hinge reversible rear door: | True |
| Door opening angle front door: | 270 ° |
| Door opening angle rear door: | 270 ° |
| Frame: | screwed together, completely pre-assembled |
| Material: | Steel |
| Model: | With permanent frame |
| Modular spacing: | 482,6 mm (19 inch) |
| Mounting level: | Front and rear |
| PHC replaceable front door: | True, according to DIN18252 (30/10 mm) |
| PHC replaceable rear door: | True |
| Packaging: | Delivery in transport packaging on a disposable pallet |
| Perforation level front door: | > 80 % |
| Perforation level rear door: | > 80 % |
| Scope of delivery: | 1x cabinet, 1 x brush strip, 1 x cage nut set (20 pieces per pack), grounding rail and grounding cable, 4 x M12 leveling feet, 2 x keys |
| Stackable: | True |
| Surface finishing: | Powder coating |
| Type of back door: | Steel perforated 1-part |
| Type of front door: | Steel perforated 1-part |
| Type of profile rail: | Crank |
| Type of ventilation: | Passive |
| With backside door: | True |
| With earthing: | True |
| With front door: | True |
| With roof plate: | True |
| With sidewall: | True |
| With socket: | False |
Variants
| ON | Label | Color | Front door locking system | Width | Depth | Max. load capacity | Material front door | Material rear door | With vertical cable management | With glazed door | Rear door locking system | Number of height units | Height | RAL-number | Number of doors | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| PRO-3388TS.P1 | 19" Server Cabinet PRO 33U, 800x800 mm, F+R 1-Part, RAL9005 | black | 3-point rod locking mechanism with swivel lever | 800 mm | 800 mm | 1000 kg | Steel | Steel | False | False | 3-point rod locking mechanism with swivel lever | 33 HE | 1563 mm | 9005 | 2 | |
| PRO-4288TS.P1 | 19" Server Cabinet PRO 42U, 800x800 mm, F+R 1-Part, RAL9005 | black | 3-point rod locking mechanism with swivel lever | 800 mm | 800 mm | 1000 kg | Steel | Steel | False | False | 3-point rod locking mechanism with swivel lever | 42 HE | 1963 mm | 9005 | 2 | |
| PRO-4288GR.P1 | 19" Server Cabinets PRO, 800x800 mm, 1-Part Doors | grey | 3-point rod locking mechanism with swivel lever | 800 mm | 800 mm | 1000 kg | Steel | Steel | False | False | 3-point rod locking mechanism with swivel lever | 42 HE | 1963 mm | 7035 | 2 | |
| PRO-4788TS.P1 | 19" Server Cabinets PRO, 800x800 mm, 1-Part Doors | black | 3-point rod locking mechanism with swivel lever | 800 mm | 800 mm | 1000 kg | Steel | Steel | False | False | 3-point rod locking mechanism with swivel lever | 47 HE | 2186 mm | 9005 | 2 |
Sikkerhedsanvisninger
Do not use the device if the cable or plug is damaged. This device may only be used in dry environments. Avoid faulty electrical connections. Only use the device within the specified voltage range. Do not block any ventilation openings to prevent components from overheating. Do not operate the appliance beyond the permissible connected loads to prevent overloading and excessive heat generation. Ensure that the device does not overheat during operation. Warning: Danger of electric shocks and short circuits! Ensure proper earthing to avoid electric shocks. Avoid overloading as this can lead to overheating and short circuits. Check that the housing is undamaged and that there are no exposed contacts or bare wires. Ensure that all electrical connections are made correctly and that the ambient conditions comply with the technical specifications. Always keep a sufficient distance from live devices and avoid misuse. Warning: Pay attention to the assembly sequence! Observe the correct assembly sequence, see instructions. Important safety information to prevent accidents and damage during installation: Hazard: If the raised floor is used incorrectly, it may break. Action: Avoid walking on the raised floor unless the correct loads and load specifications are taken into account. Incorrect loading Hazard: Incorrect loading can lead to instability and damage. Action: Ensure that the load is even and prescribed according to the manufacturer's instructions. Enclosure falls due to weight being exceeded Hazard: Exceeding the maximum weight limit can destabilize the enclosure. Action: Check the maximum permissible load of the enclosure and ensure that this is not exceeded. Falling components due to inadequate fastening Hazard: Inadequately fastened components can fall and cause injury. Action: Ensure that all parts are properly and securely assembled. Housing parts breaking out due to incorrect loading Danger: Inadmissible loading leads to material damage and possible housing parts breaking out. Action: Ensure that the load is distributed correctly and that the recommended load is used. Risk of tipping due to uneven floor Danger: An uneven floor can cause the cabinet or device to tip over. Action: Make sure that the surface is level and stable to avoid the risk of tipping. Risk of tipping due to insufficient load-bearing capacity of the surface Danger: Insufficient load-bearing capacity of the surface can encourage the cabinet to tip over. Action: Check the load-bearing capacity of the surface before installation and ensure that it can safely support the weight. Cabinet can tip over if heavy server unit is pulled forward Danger: Pulling heavy server units forward can cause the cabinet to tip over. Action: Always secure cabinets and server units with suitable brackets and seek assistance when handling heavy equipment. Risk of tipping over with heavy cooling unit without safety measures Hazard: Improper fastening of cooling units to external brackets can cause the cabinet or device to tip over. Action: Secure cooling units with suitable devices to prevent tipping. Side walls fall off - sash lock not used correctly Hazard: Incorrectly used sash locks can cause the side walls of the cabinet to fall off. Action: Regularly check that all sash locks are correctly and securely fitted. Load capacity not provided Hazard: An insufficient load capacity can destabilise the system. Action: Before installation, check the load capacity information and ensure that the base and the shelves are sufficiently stable. Inadequate fastening when fitting accessories Hazard: Loosely fitted accessories can fall down dangerously. Action: Fasten all accessories carefully and regularly check them for strength. Insufficient wall statics - housing falls down Danger: Insufficient wall statics can cause the housing to fall down. Action: Before installation, make sure that the wall has sufficient static load-bearing capacity and that the housing can be installed safely. Injury from falling attachments Danger: Insufficiently secured attachments can fall down and cause injuries. Action: Make sure that all attachments are correctly secured and check them regularly. Warning: Do not exceed the load capacity! If the specified load capacity is exceeded, serious injuries may occur due to instability of the product.
Producentangivelse