19" flat wall shelf cabinet, D=30 cm
Produktinformation til 19" flat wall shelf cabinet, D=30 cm, 12 HE one-piece, grey
Ideal for installing patch panels or power supply din rails
Robust welded structure in cold rolled steel
5mm tempered glass door, removable and reversible
A pair of uprights that can be positioned in depth at 3 levels
Constructed from 1.5mm steel plate
Complete with grounding kit and mounting kit
Maximum supported load of 30 Kg; IP20 protection
CE certification according to the EN 62208 standard
Compliance with IEC297; IEC297-1; IEC297-2; IEC297-3; EN61439-1; EN60529; EN12150-1
Compliance with the UNI EN ISO 9001: 2008 standard
Dimensions (LxHxP): 600 x 655 x 300 mm, 12U
Powder coated with RAL 7035 colors (gray)
* The image is indicative and has the sole purpose of highlighting the structure of the cabinet; for color and size refer to the product sheet
12-unit flat monobloc single-section 19" wall-mounted cabinet with reduced depth, particularly suitable for installing patch panels or Din rails for power supply
Robust welded structure in cold rolled steel
Door in 5 mm tempered glass, easily removable and reversible, 180° opening angle, lock with key
Blind rear panel
Blind side panels
Predisposition for cable entry on the base and on the roof through 6 holes with a diameter of 27 mm and 6 pre-cut rectangular profiles (70 x 30 mm)
A pair of 19" 1.5 mm uprights, adjustable in depth to three levels (maximum useful depth 270 mm with the upright fully advanced)
Slots for air passage in the upper and lower part of the front side
Tekniske egenskaber
| Degree of protection: | IP20 |
|---|---|
| Demountable: | False |
| Material: | Steel |
| Modular spacing: | 482,6 mm (19 inch) |
| Mounting level: | Front side |
| Number of cartons: | 1 |
| Number of doors: | 1 |
| Scope of delivery: | 1x Cabinet |
| Surface finishing: | powder coating |
| Type of front door: | Glass door 1-part |
| Type of ventilation: | Passive |
| With front door: | True |
Sikkerhedsanvisninger
Warning: Danger of electric shocks and short circuits! Ensure proper earthing to avoid electric shocks. Avoid overloading as this can lead to overheating and short circuits. Check that the housing is undamaged and that there are no exposed contacts or bare wires. Ensure that all electrical connections are made correctly and that the ambient conditions comply with the technical specifications. Always keep a sufficient distance from live devices and avoid misuse. Important safety information to prevent accidents and damage during installation: Hazard: If the raised floor is used incorrectly, it may break. Action: Avoid walking on the raised floor unless the correct loads and load specifications are taken into account. Incorrect loading Hazard: Incorrect loading can lead to instability and damage. Action: Ensure that the load is even and prescribed according to the manufacturer's instructions. Enclosure falls due to weight being exceeded Hazard: Exceeding the maximum weight limit can destabilize the enclosure. Action: Check the maximum permissible load of the enclosure and ensure that this is not exceeded. Falling components due to inadequate fastening Hazard: Inadequately fastened components can fall and cause injury. Action: Ensure that all parts are properly and securely assembled. Housing parts breaking out due to incorrect loading Danger: Inadmissible loading leads to material damage and possible housing parts breaking out. Action: Ensure that the load is distributed correctly and that the recommended load is used. Risk of tipping due to uneven floor Danger: An uneven floor can cause the cabinet or device to tip over. Action: Make sure that the surface is level and stable to avoid the risk of tipping. Risk of tipping due to insufficient load-bearing capacity of the surface Danger: Insufficient load-bearing capacity of the surface can encourage the cabinet to tip over. Action: Check the load-bearing capacity of the surface before installation and ensure that it can safely support the weight. Cabinet can tip over if heavy server unit is pulled forward Danger: Pulling heavy server units forward can cause the cabinet to tip over. Action: Always secure cabinets and server units with suitable brackets and seek assistance when handling heavy equipment. Risk of tipping over with heavy cooling unit without safety measures Hazard: Improper fastening of cooling units to external brackets can cause the cabinet or device to tip over. Action: Secure cooling units with suitable devices to prevent tipping. Side walls fall off - sash lock not used correctly Hazard: Incorrectly used sash locks can cause the side walls of the cabinet to fall off. Action: Regularly check that all sash locks are correctly and securely fitted. Load capacity not provided Hazard: An insufficient load capacity can destabilise the system. Action: Before installation, check the load capacity information and ensure that the base and the shelves are sufficiently stable. Inadequate fastening when fitting accessories Hazard: Loosely fitted accessories can fall down dangerously. Action: Fasten all accessories carefully and regularly check them for strength. Insufficient wall statics - housing falls down Danger: Insufficient wall statics can cause the housing to fall down. Action: Before installation, make sure that the wall has sufficient static load-bearing capacity and that the housing can be installed safely. Injury from falling attachments Danger: Insufficiently secured attachments can fall down and cause injuries. Action: Make sure that all attachments are correctly secured and check them regularly.