Gå til hovedindhold Spring til søgning Gå til hovednavigation
Indkøbskurv

Cat.6A/classEA Installation link, S/FTP, 50m on drum

Produktinformation til Cat.6A/classEA Installation link, S/FTP, 50m on drum

Robust special rubber cable drum, complete with Cat.7 S/FTP installation cable, integrated outlet Cat.6A 1 x RJ45 with dust cap and 1 x Cat.6A RJ45. Very well suited to mobile use, for exhibitions, presentations, outside broadcasting vans, measuring sections etc. A standardised installation section in accordance with structured cabling Cat.6A / Class EA.
AWG-size: 23
Allocation: acc. TIA/EIA 568B
Anti-kink sleeve: none
Bending radius: 4 x OD
Cable construction: 4x2
Cable shape: rund
Cable type: S/FTP
Cabling standard: ISO/IEC 11801
Category: 6A (TIA)
Colour anti-kink sleeve: black
Colour outer sheath: orange
Conductive shield: 360° shield contact
Conductor Material: Copper
Contacts: Gold plated
Dust cover: True
Fire retardant version: True
Length imprint: False
Locking lever: False
Low smoke: acc. IEC61034
Material outer sheath: FRNC
Model: shielded
NVP value: 79 %
Oil resistant: no
Operating Temperature: -20 – 60 °C
Ozone resistance: No
Pin assignment: 1:1
Raw cable: Cat.7
Resistant to chemicals: False
Test voltage: 1000 (V DC, 1min) core/core und core/screen
Transmission: 10Gbit
Type of connector connection 1: RJ45 8(8)
Type of connector connection 2: RJ45 8(8)
UL approbated: False
UV resistant: Nein

Tekniske egenskaber

AWG-size: 23
Allocation: acc. TIA/EIA 568B
Anti-kink sleeve: none
Bending radius: 4 x OD
Cable construction: 4x2
Cable shape: rund
Cable type: S/FTP
Cabling standard: ISO/IEC 11801
Category: 6A (TIA)
Colour anti-kink sleeve: black
Colour outer sheath: orange
Conductive shield: 360° shield contact
Conductor Material: Copper
Contacts: Gold plated
Dust cover: True
Fire retardant version: True
Length imprint: False
Locking lever: False
Low smoke: acc. IEC61034
Material outer sheath: FRNC
Model: shielded
NVP value: 79 %
Oil resistant: no
Operating Temperature: -20 – 60 °C
Ozone resistance: No
Pin assignment: 1:1
Raw cable: Cat.7
Resistant to chemicals: False
Test voltage: 1000 (V DC, 1min) core/core und core/screen
Transmission: 10Gbit
Type of connector connection 1: RJ45 8(8)
Type of connector connection 2: RJ45 8(8)
UL approbated: False
UV resistant: Nein

Varianter

Art. Nej. Betegnelse Length
K9201.50 Cat.6A/classEA Installation link, S/FTP, 50m on drum 50.0 m
K9201.90 Cat.6A/classEA Installation link, S/FTP, 90m on drum 90.0 m

Produktinformation til Cat.6A/classEA Installation link, S/FTP, 50m on drum

Robust special rubber cable drum, complete with Cat.7 S/FTP installation cable, integrated outlet Cat.6A 1 x RJ45 with dust cap and 1 x Cat.6A RJ45. Very well suited to mobile use, for exhibitions, presentations, outside broadcasting vans, measuring sections etc. A standardised installation section in accordance with structured cabling Cat.6A / Class EA.
AWG-size: 23
Allocation: acc. TIA/EIA 568B
Anti-kink sleeve: none
Bending radius: 4 x OD
Cable construction: 4x2
Cable shape: rund
Cable type: S/FTP
Cabling standard: ISO/IEC 11801
Category: 6A (TIA)
Colour anti-kink sleeve: black
Colour outer sheath: orange
Conductive shield: 360° shield contact
Conductor Material: Copper
Contacts: Gold plated
Dust cover: True
Fire retardant version: True
Length imprint: False
Locking lever: False
Low smoke: acc. IEC61034
Material outer sheath: FRNC
Model: shielded
NVP value: 79 %
Oil resistant: no
Operating Temperature: -20 – 60 °C
Ozone resistance: No
Pin assignment: 1:1
Raw cable: Cat.7
Resistant to chemicals: False
Test voltage: 1000 (V DC, 1min) core/core und core/screen
Transmission: 10Gbit
Type of connector connection 1: RJ45 8(8)
Type of connector connection 2: RJ45 8(8)
UL approbated: False
UV resistant: Nein

AWG-size: 23
Allocation: acc. TIA/EIA 568B
Anti-kink sleeve: none
Bending radius: 4 x OD
Cable construction: 4x2
Cable shape: rund
Cable type: S/FTP
Cabling standard: ISO/IEC 11801
Category: 6A (TIA)
Colour anti-kink sleeve: black
Colour outer sheath: orange
Conductive shield: 360° shield contact
Conductor Material: Copper
Contacts: Gold plated
Dust cover: True
Fire retardant version: True
Length imprint: False
Locking lever: False
Low smoke: acc. IEC61034
Material outer sheath: FRNC
Model: shielded
NVP value: 79 %
Oil resistant: no
Operating Temperature: -20 – 60 °C
Ozone resistance: No
Pin assignment: 1:1
Raw cable: Cat.7
Resistant to chemicals: False
Test voltage: 1000 (V DC, 1min) core/core und core/screen
Transmission: 10Gbit
Type of connector connection 1: RJ45 8(8)
Type of connector connection 2: RJ45 8(8)
UL approbated: False
UV resistant: Nein

Varianter

Art. Nej. Betegnelse Length
K9201.50 Cat.6A/classEA Installation link, S/FTP, 50m on drum 50.0 m
K9201.90 Cat.6A/classEA Installation link, S/FTP, 90m on drum 90.0 m

Sikkerhedsanvisninger


Warning: Danger of electric shocks and short circuits! Ensure proper earthing to avoid electric shocks. Avoid overloading as this can lead to overheating and short circuits. Check that the housing is undamaged and that there are no exposed contacts or bare wires. Ensure that all electrical connections are made correctly and that the ambient conditions comply with the technical specifications. Always keep a sufficient distance from live devices and avoid misuse.

Producentangivelse


EFB-Elektronik GmbH   
Striegauer Straße 1   
33719 Bielefeld   
info@efb-elektronik.de    
https://www.efb-elektronik.de/kontakt